Educational draft — scientific review incomplete
A tablet press has exceeded its critical lubrication PM date by nine days but produced two lots without alarms. What should QA evaluate?
Control future use, investigate actual wear and lubrication state, and assess the two exposed lots using more than the absence of alarms.