PHARMATALKSPHARMACEUTICAL KNOWLEDGE
Pharmatalks / Department Collection

Manufacturing SOP Library

30 English SOP guides with evidence checklists and records.

Manufacturing · 30 SOPs

Manufacturing, equipment use, in-process controls, packaging, material handling and sterile operations.

PRD-001 · Manufacturing

Dispensing of raw materials

Control material identity, status, weights and independently checked dispensing.

PRD-002 · Manufacturing

Batch manufacturing record

Record execution contemporaneously and reconcile approved manufacturing instructions.

PRD-003 · Manufacturing

Gowning and entry to production areas

Prevent contamination by controlling personnel entry sequence and gowning.

PRD-004 · Manufacturing

Personnel hygiene and health

Define health, hygiene and behaviour expectations for exposed product operations.

PRD-005 · Manufacturing

Cleaning and sanitisation of production areas

Apply approved area-cleaning agents, frequencies and effectiveness verification.

PRD-006 · Manufacturing

Equipment cleaning and status labelling

Demonstrate equipment cleanliness and accurate status labelling before use.

PRD-007 · Manufacturing

Product changeover

Document product-changeover line clearance and potential carryover risks.

PRD-008 · Manufacturing

Sifting and milling

Control sieve identity, particle size requirements and milling parameter records.

PRD-009 · Manufacturing

High-shear granulator

Maintain approved mixing/granulation parameters and end-point checks.

PRD-010 · Manufacturing

Fluid bed dryer

Control drying temperature, time and end-point moisture measurement.

PRD-011 · Manufacturing

Blender

Verify blending load, sequence, duration and blend uniformity strategy.

PRD-012 · Manufacturing

Tablet press

Control tablet press setup, tooling, compression and in-process trend response.

PRD-013 · Manufacturing

Punches and dies

Inspect and maintain tool identification, wear, defects and segregation.

PRD-014 · Manufacturing

Tablet coating

Monitor coating recipe, spray rate, inlet conditions and coating attributes.

PRD-015 · Manufacturing

Capsule filling machine

Check capsule filling setup, fill weight, capsule integrity and reconciliation.

PRD-016 · Manufacturing

Manufacturing vessel and homogeniser

Record mixing, temperature and homogenisation parameters for vessel operations.

PRD-017 · Manufacturing

Liquid filling and capping

Verify fill volume, closure integrity, capping and line controls.

PRD-018 · Manufacturing

Tube filling and sealing

Control tube filling setup, fill weight and seal integrity verification.

PRD-019 · Manufacturing

Blister packaging

Verify blister coding, seal integrity, component identity and reconciliation.

PRD-020 · Manufacturing

Secondary packaging and reconciliation

Reconcile labels, cartons and leaflets and prevent product/package mix-ups.

PRD-021 · Manufacturing

In-process controls

Set clear in-process test points, decision limits and line escalation rules.

PRD-022 · Manufacturing

Yield calculation and reconciliation

Explain yield variation with documented theoretical and actual reconciliation.

PRD-023 · Manufacturing

Intermediate and bulk products

Define hold times, identification and transfer controls for intermediate and bulk materials.

PRD-024 · Manufacturing

Metal detection

Demonstrate metal detector challenge checks and response to reject failures.

PRD-025 · Manufacturing

Production waste

Segregate and account for waste without cross-contaminating active areas.

PRD-026 · Manufacturing

Aseptic filling

Maintain aseptic protection, critical interventions and fill-line monitoring.

PRD-027 · Manufacturing

Aseptic process simulation

Use approved simulation conditions and document operator interventions.

PRD-028 · Manufacturing

Steam sterilisation

Control sterilisation cycle parameters, load patterns and independent release review.

PRD-029 · Manufacturing

Depyrogenation

Verify endotoxin-reduction cycle, thermal mapping and load configuration.

PRD-030 · Manufacturing

Filter integrity testing

Demonstrate pre-/post-use filter integrity and filter-system compatibility.