CAPA Reopening Rule
Direct definition
A defined basis for revisiting a CAPA when follow-up findings contradict its original effectiveness conclusion.
Detailed technical explanation
Reopening or linking a new investigation may be appropriate after recurrence, ineffective controls, misleading evidence, newly affected products or an unanticipated harm. Record why the former conclusion changed and reassess immediate product impact; do not hide the history by silently editing closure dates.
Practical example
After a supposedly effective alarm retrofit, a new batch shows the same unannunciated high-temperature exposure.
Why it matters
CAPA actions should protect patients by controlling confirmed and credible quality failure mechanisms, not merely by closing administrative tasks.
Common misconception
A closed CAPA can never be challenged.
Reference sections
ICH Q10 §3.2.2; 21 CFR 211.192 for relevant batch discrepancies
Source references — not yet verified
- ICH — ICH Q10 Pharmaceutical Quality System — Step 4 guideline (2008)
Source supplied with the draft; version and applicability not verified.
Source register link — unverified applicability - US FDA — 21 CFR 211.192 — Production Record Review (including unexplained discrepancies and scope extension)
Source supplied with the draft; version and applicability not verified.
Source register link — unverified applicability
Review and applicability
Scientific review incomplete. No scientific reviewer, approval date or regulatory endorsement is claimed.
Educational information. Apply the relevant jurisdiction, product context and approved site quality system.