Data migration verification
Direct definition
Evidence that regulated records and associated context remain complete, accurate and usable after system migration.
Detailed technical explanation
Define source and target records, transforms, reconciliation counts, exception resolution, metadata, audit-trail retention, linkage and readability of historical records; verify samples proportional to risk and complexity.
Practical example
ILLUSTRATIVE HYPOTHETICAL CASE — At a regulated pharmaceutical site, a chromatography system records a reintegrated peak and retains the previous integration history. The team records the configuration, intended GMP use, observed result, risk-based acceptance evidence and quality impact; this example is not a real batch event.
Why it matters
It prevents irreversible loss or distortion of evidence during technology replacement.
Pharmaceutical applications
It prevents irreversible loss or distortion of evidence during technology replacement.
Common misconception
Matching the number of imported rows proves every regulated field is correct.
Source references — not yet verified
- Source register — 21 CFR 211.68 — Automatic, mechanical, and electronic equipment
Source supplied with the draft; version and applicability not verified.
Source register link — unverified applicability - Source register — EU GMP Annex 11 — Computerised Systems
Source supplied with the draft; version and applicability not verified.
Source register link — unverified applicability - Source register — ICH Q9(R1) — Quality Risk Management
Source supplied with the draft; version and applicability not verified.
Source register link — unverified applicability - Source register — ISPE GAMP 5 Second Edition (2022) — A Risk-Based Approach to Compliant GxP Computerized Systems
Source supplied with the draft; version and applicability not verified.
Source register link — unverified applicability - Source register — FDA — Data Integrity and Compliance With Drug CGMP: Questions and Answers (2018)
Source supplied with the draft; version and applicability not verified.
Source register link — unverified applicability - Source register — PIC/S PI 041 — Good Practices for Data Management and Integrity in Regulated GMP/GDP Environments
Source supplied with the draft; version and applicability not verified.
Source register link — unverified applicability - Source register — 21 CFR 211.180 — General requirements for records and reports
Source supplied with the draft; version and applicability not verified.
Source register link — unverified applicability
Review and applicability
Scientific review incomplete. No scientific reviewer, approval date or regulatory endorsement is claimed.
Educational information. Apply the relevant jurisdiction, product context and approved site quality system.