Maximum allowable carryover (MACO)
Direct definition
An equipment/process-specific maximum residue amount calculated using a justified exposure-based criterion and assumptions for the subsequent product.
Detailed technical explanation
A common conceptual scaling uses PDE, the next product minimum batch size and its maximum daily dose with consistent units; allocation across a train requires an explicit rationale.
Practical example
ILLUSTRATIVE — In a hypothetical manufacturing setting, a validation team challenges the maximum dirty hold with a dried, high-solids residue on representative surface material. The scenario is educational; it is not an actual batch record or universally approved acceptance criterion.
Why it matters
Using this concept correctly changes which hazards, controls or qualification evidence must be assessed: Translating a safety criterion into a residue budget for a product changeover..
Pharmaceutical applications
Translating a safety criterion into a residue budget for a product changeover.
Common misconception
MACO can be copied from another line without checking product and equipment assumptions.
Source references — not yet verified
- Source register — European Commission EU GMP Annex 15 — Qualification and Validation (Cleaning Validation, §10)
Source supplied with the draft; version and applicability not verified.
Source register link — unverified applicability - Source register — European Commission EU GMP Chapter 5 — Production
Source supplied with the draft; version and applicability not verified.
Source register link — unverified applicability - Source register — 21 CFR 211.67 — Equipment cleaning and maintenance
Source supplied with the draft; version and applicability not verified.
Source register link — unverified applicability - Source register — EMA Guideline on setting health-based exposure limits in shared facilities (EMA/CHMP/CVMP/SWP/169430/2012; effective 2015)
Source supplied with the draft; version and applicability not verified.
Source register link — unverified applicability - Source register — EMA Questions and Answers on implementation of risk-based prevention of cross-contamination (EMA/CHMP/CVMP/SWP/246844/2018)
Source supplied with the draft; version and applicability not verified.
Source register link — unverified applicability
Review and applicability
Scientific review incomplete. No scientific reviewer, approval date or regulatory endorsement is claimed.
Educational information. Apply the relevant jurisdiction, product context and approved site quality system.