Out-of-Specification Investigation
Direct definition
A formal assessment of a test result outside an established acceptance criterion, including laboratory and potentially manufacturing causes.
Detailed technical explanation
FDA’s May 2022 OOS guidance describes a scientifically sound investigation approach. Initial laboratory review can identify clear analytical errors; absent a substantiated cause, a broader investigation should examine material, sampling, manufacturing and associated batches as appropriate. Retest and resample plans need prior scientific justification. Batch disposition must consider the full evidence and applicable requirements rather than a selectively chosen final average.
Practical example
An OOS assay result remains part of the batch investigation even after a later replicate produces an in-range value.
Source references — not yet verified
- US FDA — Investigating Out-of-Specification (OOS) Test Results for Pharmaceutical Production, May 2022
Source supplied with the draft; version and applicability not verified.
Source register link — unverified applicability - US FDA / eCFR — 21 CFR 211.192 — Production Record Review
Source supplied with the draft; version and applicability not verified.
Source register link — unverified applicability
Review and applicability
Scientific review incomplete. No scientific reviewer, approval date or regulatory endorsement is claimed.
Educational information. Apply the relevant jurisdiction, product context and approved site quality system.