Breakdown investigation
Direct definition
Systematic inquiry into a failure event and its impact, mechanism, root or contributing causes and recurrence risk.
Detailed technical explanation
Evidence may include sensor trends, alarm logs, operator accounts, replaced-part examination, repair history and product genealogy. Investigation should distinguish physical root cause, systemic causes and detection failure.
Practical example
ILLUSTRATIVE HYPOTHETICAL CASE — At a pharmaceutical site, a maintenance ticket is closed without recording an interlock functional challenge. Engineers and Quality evaluate the relevant failure mechanism, affected process window, equipment status, verified tests and possible product impact.
Why it matters
It prevents repetitive failures and supports justified product, batch and equipment disposition.
Pharmaceutical applications
It prevents repetitive failures and supports justified product, batch and equipment disposition.
Common misconception
Replacing the broken component completes the investigation.
Source references — not yet verified
- Source register — 21 CFR 211.67 — Equipment cleaning and maintenance
Source supplied with the draft; version and applicability not verified.
Source register link — unverified applicability - Source register — EU GMP Chapter 3 — Premises and Equipment
Source supplied with the draft; version and applicability not verified.
Source register link — unverified applicability - Source register — ICH Q9(R1) — Quality Risk Management
Source supplied with the draft; version and applicability not verified.
Source register link — unverified applicability - Source register — EU GMP Chapter 4 — Documentation
Source supplied with the draft; version and applicability not verified.
Source register link — unverified applicability - Source register — 21 CFR 211.180 — General requirements for records and reports
Source supplied with the draft; version and applicability not verified.
Source register link — unverified applicability - Source register — 21 CFR 211.182 — Equipment cleaning and use log
Source supplied with the draft; version and applicability not verified.
Source register link — unverified applicability - Source register — 21 CFR 211.68 — Automatic, mechanical, and electronic equipment
Source supplied with the draft; version and applicability not verified.
Source register link — unverified applicability - Source register — 21 CFR 211.63 — Equipment design, size, and location
Source supplied with the draft; version and applicability not verified.
Source register link — unverified applicability
Review and applicability
Scientific review incomplete. No scientific reviewer, approval date or regulatory endorsement is claimed.
Educational information. Apply the relevant jurisdiction, product context and approved site quality system.